The example I've shown is direct absolute addressing.
#SIEMENS STEP 7 STUCK ON CHECK BEFORE LOADING CODE#
For example -Įvery time this section of code is executed it will read the same two inputs and control the same output.
#SIEMENS STEP 7 STUCK ON CHECK BEFORE LOADING SOFTWARE#
Somewhere in the PLC programming software there will have to be a table of some sort relating each of these symbolic names to an absolute address.ĭirect : a reference to a memory location within the PLC where it is explictly identified during editing and will not change dynamically at runtime. Examples here could be "WaterLevel", "DirnIndicator", "AV1037" etc. Symbolic : a reference to a memory location within the PLC using an alias or synonym assigned by the user. These addresses identify the location and size (bit, byte, word etc) of the the memory being referenced, but nothing more. My use of these means :Ībsolute : a reference to a memory location within the PLC made using the manufacture's own designation for that memory. We've got four terms here : absolute, symbolic, direct, indirect. We love to make life difficult for ourselves, don't we! Once you are used to it, troubleshooting is a cinch. I can then open this file with the block editor and do a search on any variable. I select all of the FCs and FBs, and it generates a text file of all of the code. Since the cross reference list is useless in my case, this is what I do: I open a block, click FILE, and choose Generate Source. Of course, sometimes a person just has to be able to cross-reference a variable. Ultimately, I end up with nice clean code that is very easy to maintain and can be reused over and over without making any changes whatsoever. The physical IO bits are mapped to data bits, and I manipulate the data bits in my code, and transfer the results to the output card at the end of OB1 (again, based on the configuration). Even the timers are assigned dynamically in the startup block, because I don't want to worry later if they have already been used or not. So, technically, very little of what I do can be referenced through the cross reference list. This makes it nice for troubleshooting and development, because I don't have to open VAT tables or maintain a bunch of instance DBs. Then, if I had a machine with 20 similar components on it (perhaps 20 conveyors with motors and drives), I could just create a single shared DB with an array of the 20 components and loop through them. I just define a UDT as the stat variable, and manipulate AR2 dynamically so that I point to the correct bits. And, I always program with symbolic priority so that I don't have to care what the absolute addresses of any data bits are (if I have to insert a new variable in a UDT, it just moves the other variables down and uses the new addresses after I recompile).Īlso, I prefer to call my FBs unconditionally without an instance DB or input parameters.
![siemens step 7 stuck on check before loading siemens step 7 stuck on check before loading](https://blogs.vmware.com/teamfusion/files/2020/05/3dMark-Fusion-dx11-scaled-576x324.png)
But, I like to keep my code completely generic so that I don't have specific code for each site. Most of the systems I have programmed have been configurable, i.e. I'll try to explain myself a little better.